mirror of
				https://github.com/riscv-software-src/opensbi
				synced 2025-11-04 14:00:31 +00:00 
			
		
		
		
	Noisy commit, no functional changes. Generated with an current upstream clang-format and: clang-format -i $(find . -name \*.[ch]) Signed-off-by: Olof Johansson <olof@lixom.net>
		
			
				
	
	
		
			241 lines
		
	
	
		
			4.7 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
			
		
		
	
	
			241 lines
		
	
	
		
			4.7 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
/*
 | 
						|
 * SPDX-License-Identifier: BSD-2-Clause
 | 
						|
 *
 | 
						|
 * Copyright (c) 2019 Western Digital Corporation or its affiliates.
 | 
						|
 */
 | 
						|
 | 
						|
#include <sbi/riscv_encoding.h>
 | 
						|
#include <sbi/sbi_const.h>
 | 
						|
#include <sbi/sbi_platform.h>
 | 
						|
 | 
						|
/*
 | 
						|
 * Include these files as needed.
 | 
						|
 * See config.mk PLATFORM_xxx configuration parameters.
 | 
						|
 */
 | 
						|
#include <plat/irqchip/plic.h>
 | 
						|
#include <plat/serial/uart8250.h>
 | 
						|
#include <plat/sys/clint.h>
 | 
						|
 | 
						|
/*
 | 
						|
 * Platform early initialization.
 | 
						|
 */
 | 
						|
static int platform_early_init(bool cold_boot)
 | 
						|
{
 | 
						|
	return 0;
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Platform final initialization.
 | 
						|
 */
 | 
						|
static int platform_final_init(bool cold_boot)
 | 
						|
{
 | 
						|
	return 0;
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Get number of PMP regions for given HART.
 | 
						|
 */
 | 
						|
static u32 platform_pmp_region_count(u32 hartid)
 | 
						|
{
 | 
						|
	return 0;
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Get PMP regions details (namely: protection, base address, and size) for
 | 
						|
 * a given HART.
 | 
						|
 */
 | 
						|
static int platform_pmp_region_info(u32 hartid, u32 index, ulong *prot,
 | 
						|
				    ulong *addr, ulong *log2size)
 | 
						|
{
 | 
						|
	return 0;
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Initialize the platform console.
 | 
						|
 */
 | 
						|
static int platform_console_init(void)
 | 
						|
{
 | 
						|
	/* Example if the generic UART8250 driver is used */
 | 
						|
	return uart8250_init(PLATFORM_UART_ADDR, PLATFORM_UART_SHIFTREG_ADDR,
 | 
						|
			     PLATFORM_UART_BAUDRATE, 0, 1);
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Write a character to the platform console output.
 | 
						|
 */
 | 
						|
static void platform_console_putc(char ch)
 | 
						|
{
 | 
						|
	/* Example if the generic UART8250 driver is used */
 | 
						|
	uart8250_putc(ch);
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Read a character from the platform console input.
 | 
						|
 */
 | 
						|
static int platform_console_getc(void)
 | 
						|
{
 | 
						|
	return uart8250_getc();
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Initialize the platform interrupt controller for current HART.
 | 
						|
 */
 | 
						|
static int platform_irqchip_init(bool cold_boot)
 | 
						|
{
 | 
						|
	u32 hartid = sbi_current_hartid();
 | 
						|
	int ret;
 | 
						|
 | 
						|
	/* Example if the generic PLIC driver is used */
 | 
						|
	if (cold_boot) {
 | 
						|
		ret = plic_cold_irqchip_init(PLATFORM_PLIC_ADDR,
 | 
						|
					     PLATFORM_PLIC_NUM_SOURCES,
 | 
						|
					     PLATFORM_HART_COUNT);
 | 
						|
		if (ret)
 | 
						|
			return ret;
 | 
						|
	}
 | 
						|
 | 
						|
	return plic_warm_irqchip_init(hartid, 2 * hartid, 2 * hartid + 1);
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Initialize IPI for current HART.
 | 
						|
 */
 | 
						|
static int platform_ipi_init(bool cold_boot)
 | 
						|
{
 | 
						|
	int ret;
 | 
						|
 | 
						|
	/* Example if the generic CLINT driver is used */
 | 
						|
	if (cold_boot) {
 | 
						|
		ret = clint_cold_ipi_init(PLATFORM_CLINT_ADDR,
 | 
						|
					  PLATFORM_HART_COUNT);
 | 
						|
		if (ret)
 | 
						|
			return ret;
 | 
						|
	}
 | 
						|
 | 
						|
	return clint_warm_ipi_init();
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Send IPI to a target HART
 | 
						|
 */
 | 
						|
static void platform_ipi_send(u32 target_hart)
 | 
						|
{
 | 
						|
	/* Example if the generic CLINT driver is used */
 | 
						|
	clint_ipi_send(target_hart);
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Wait for target HART to acknowledge IPI.
 | 
						|
 */
 | 
						|
static void platform_ipi_sync(u32 target_hart)
 | 
						|
{
 | 
						|
	/* Example if the generic CLINT driver is used */
 | 
						|
	clint_ipi_sync(target_hart);
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Clear IPI for a target HART.
 | 
						|
 */
 | 
						|
static void platform_ipi_clear(u32 target_hart)
 | 
						|
{
 | 
						|
	/* Example if the generic CLINT driver is used */
 | 
						|
	clint_ipi_clear(target_hart);
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Initialize platform timer for current HART.
 | 
						|
 */
 | 
						|
static int platform_timer_init(bool cold_boot)
 | 
						|
{
 | 
						|
	int ret;
 | 
						|
 | 
						|
	/* Example if the generic CLINT driver is used */
 | 
						|
	if (cold_boot) {
 | 
						|
		ret = clint_cold_timer_init(PLATFORM_CLINT_ADDR,
 | 
						|
					    PLATFORM_HART_COUNT);
 | 
						|
		if (ret)
 | 
						|
			return ret;
 | 
						|
	}
 | 
						|
 | 
						|
	return clint_warm_timer_init();
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Get platform timer value.
 | 
						|
 */
 | 
						|
static u64 platform_timer_value(void)
 | 
						|
{
 | 
						|
	/* Example if the generic CLINT driver is used */
 | 
						|
	return clint_timer_value();
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Start platform timer event for current HART.
 | 
						|
 */
 | 
						|
static void platform_timer_event_start(u64 next_event)
 | 
						|
{
 | 
						|
	/* Example if the generic CLINT driver is used */
 | 
						|
	clint_timer_event_start(next_event);
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Stop platform timer event for current HART.
 | 
						|
 */
 | 
						|
static void platform_timer_event_stop(void)
 | 
						|
{
 | 
						|
	/* Example if the generic CLINT driver is used */
 | 
						|
	clint_timer_event_stop();
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Reboot the platform.
 | 
						|
 */
 | 
						|
static int platform_system_reboot(u32 type)
 | 
						|
{
 | 
						|
	return 0;
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Shutdown or poweroff the platform.
 | 
						|
 */
 | 
						|
static int platform_system_shutdown(u32 type)
 | 
						|
{
 | 
						|
	return 0;
 | 
						|
}
 | 
						|
 | 
						|
/*
 | 
						|
 * Platform descriptor.
 | 
						|
 */
 | 
						|
const struct sbi_platform platform = {
 | 
						|
 | 
						|
	.name		    = "platform-name",
 | 
						|
	.features	    = SBI_PLATFORM_DEFAULT_FEATURES,
 | 
						|
	.hart_count	    = 1,
 | 
						|
	.hart_stack_size    = 4096,
 | 
						|
	.disabled_hart_mask = 0,
 | 
						|
 | 
						|
	.early_init = platform_early_init,
 | 
						|
	.final_init = platform_final_init,
 | 
						|
 | 
						|
	.pmp_region_count = platform_pmp_region_count,
 | 
						|
	.pmp_region_info  = platform_pmp_region_info,
 | 
						|
 | 
						|
	.console_init = platform_console_init,
 | 
						|
	.console_putc = platform_console_putc,
 | 
						|
	.console_getc = platform_console_getc,
 | 
						|
 | 
						|
	.irqchip_init = platform_irqchip_init,
 | 
						|
	.ipi_init     = platform_ipi_init,
 | 
						|
	.ipi_send     = platform_ipi_send,
 | 
						|
	.ipi_sync     = platform_ipi_sync,
 | 
						|
	.ipi_clear    = platform_ipi_clear,
 | 
						|
 | 
						|
	.timer_init	   = platform_timer_init,
 | 
						|
	.timer_value	   = platform_timer_value,
 | 
						|
	.timer_event_start = platform_timer_event_start,
 | 
						|
	.timer_event_stop  = platform_timer_event_stop,
 | 
						|
 | 
						|
	.system_reboot	 = platform_system_reboot,
 | 
						|
	.system_shutdown = platform_system_shutdown
 | 
						|
};
 |