Updated PLL driver sequencing requires us to use udelay in the PLL
driver as there is no poll bit to get the status of operations.
tick-timer(mcu_timer0/main_timer0) setting up the clocks for itself is
something that won't work as the PLL driver will be using udelay and
PLLs are configured during clock probe which would end up in a recursive
probe.
tick-timer being used by K3 devices are configured by ROM and we really
don't need to configure any of the clocks.
Remove the clock dependency from R5 stage as we don't need to setup
clocks for it.
Signed-off-by: Manorit Chawdhry <m-chawdhry@ti.com>
This extra binding is non-standard and now unneeded as we bind the
sysreset driver automatically. This matches what is done in Linux
and allows us to more closely match the DTBs. Remove the binding
and all users.
Signed-off-by: Andrew Davis <afd@ti.com>
Reviewed-by: Neha Malcom Francis <n-francis@ti.com>
Tested-by: Jonathan Humphreys <j-humphreys@ti.com>
Introduce the base dts files needed for u-boot or to augment the
linux dtbs for use in the u-boot-spl and u-boot binaries
Signed-off-by: Vignesh Raghavendra <vigneshr@ti.com>
Signed-off-by: Bryan Brattlof <bb@ti.com>