To ease debugging, use dev_err() instead of dev_dbg() for
alerting when regulator has nonunique value.
Signed-off-by: Patrice Chotard <patrice.chotard@foss.st.com>
Reviewed-by: Quentin Schulz <quentin.schulz@cherry.de>
Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com>
Replace some debug() by dev_dbg() when dev variable
is available/valid.
Signed-off-by: Patrice Chotard <patrice.chotard@foss.st.com>
Reviewed-by: Quentin Schulz <quentin.schulz@cherry.de>
Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com>
Both regulators_enable_boot_on/off() are unused and superseded by
regulator uclass regulator_post_probe(). Remove both functions.
Signed-off-by: Marek Vasut <marex@denx.de>
Turn regulators_enable_boot_on() and regulators_enable_boot_off() into
empty functions. Implement matching functionality in regulator_post_probe()
instead. The regulator_post_probe() is called for all regulators after they
probe, and regulators that have regulator-always-on or regulator-boot-on DT
properties now always probe due to DM_FLAG_PROBE_AFTER_BIND being set on
such regulators in regulator_post_bind().
Finally, fold regulator_unset() functionality into regulator_autoset().
Signed-off-by: Marek Vasut <marex@denx.de>
In case a regulator DT node contains regulator-always-on or regulator-boot-on
property, make sure the regulator gets correctly configured by U-Boot on start
up. Unconditionally probe such regulator drivers. This is a preparatory patch
for introduction of .regulator_post_probe() which would trigger the regulator
configuration.
Parsing of regulator-always-on and regulator-boot-on DT property has been
moved to regulator_post_bind() as the information is required early, the
rest of the DT parsing has been kept in regulator_pre_probe() to avoid
slowing down the boot process.
Signed-off-by: Marek Vasut <marex@denx.de>
dev_get_driver_ops() may return NULL when the udevice is invalid.
Move the ops check to top of functions to consistently return -ENOSYS
when ops is unimplemented and prevent trying to access uclass plat data,
also add missing NULL checks to suspend ops.
Signed-off-by: Jonas Karlman <jonas@kwiboo.se>
On some boards a PMIC regulator is flagged with regulator-on-in-suspend
and does not define any suspend or max microvolt, e.g. on Radxa ROCK 3A:
vcc_ddr: DCDC_REG3 {
regulator-name = "vcc_ddr";
regulator-always-on;
regulator-boot-on;
regulator-initial-mode = <0x2>;
regulator-state-mem {
regulator-on-in-suspend;
};
};
This result in suspend_uV having the value -ENODATA after probe.
This negative voltage, -ENODATA, gets missinterpreted and result in an
unexpected voltage being set by autoset.
E.g. on Radxa ROCK 3A the vcc_ddr regulator by default have a normal and
suspend voltage value of 0.5v. However, due to this missinterpretation
the suspend voltage end up beind set to 0.5625v instead.
Fix this by skip calling regulator_set_suspend_value() in autoset and
also protect calling set value ops when input value is -ENODATA.
Signed-off-by: Jonas Karlman <jonas@kwiboo.se>
With a recent change, regulators_enable_boot_on() returns an error if a
regulator is already set. Check for and handle this situation.
Fixes: d99fb64a98a power: regulator: Only run autoset once for each regulator
Reviewed-by: Jonas Karlman <jonas@kwiboo.se>
Reviewed-by: Quentin Schulz <quentin.schulz@cherry.de>
Signed-off-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Quentin Schulz <quentin.schulz@cherry.de>
Reviewed-by: Jonas Karlman <jonas@kwiboo.se>
As part of bringing the master branch back in to next, we need to allow
for all of these changes to exist here.
Reported-by: Jonas Karlman <jonas@kwiboo.se>
Signed-off-by: Tom Rini <trini@konsulko.com>
When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay
Ethernet"' I failed to notice that b4 noticed it was based on next and
so took that as the base commit and merged that part of next to master.
This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing
changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35.
Reported-by: Jonas Karlman <jonas@kwiboo.se>
Signed-off-by: Tom Rini <trini@konsulko.com>
With the commit 4fcba5d556b4 ("regulator: implement basic reference
counter"), keeping regulator enablement in balance become more important.
Calling regulator_autoset multiple times on a fixed regulator increase
the enable count for each call, resulting in an unbalanced enable count.
Introduce a AUTOSET_DONE flag and use it to mark that autoset has run
for the regulator. Return -EALREADY on any subsequent call to autoset.
This fixes so that the enable count is only ever increased by one per
regulator for autoset.
Fixes: 4fcba5d556b4 ("regulator: implement basic reference counter")
Signed-off-by: Jonas Karlman <jonas@kwiboo.se>
Reviewed-by: Kever Yang <kever.yang@rock-chips.com>
The regulator core can return different codes which are not considered
a real error for this function.
Return success in such cases.
Signed-off-by: Eugen Hristev <eugen.hristev@collabora.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Patrice Chotard <patrice.chotard@foss.st.com>
If a regulator does not support .set_suspend_enable or
.set_suspend_value then ret is set to ENOSYS early in the function.
The most serious impact of this is that when no automatic setting of
voltage is needed then the final regulator_set_enable() is skipped
because ret has not been cleared.
It seems that the error handling for regulator_set_suspend_value() is
also wrong as if this succeeds then the normal boot-on checks are still
required, and again ENOSYS needs special treatment here.
Fixes: 11406b8f7e ("dm: regulator: support regulator more state")
Signed-off-by: John Keeping <john@metanate.com>
Define LOG_CATEGORY for all uclass to allow filtering with
log command.
Signed-off-by: Patrick Delaunay <patrick.delaunay@foss.st.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Add support for regulator-force-boot-off DT property.
This property can be used by the board/device drivers for
turning off regulators on early init stages as pre-requisite
for the other components initialization.
Signed-off-by: Konstantin Porotchkin <kostap@marvell.com>
Signed-off-by: Stefan Roese <sr@denx.de>
Cc: Jaehoon Chung <jh80.chung@samsung.com>
Cc: Simon Glass <sjg@chromium.org>
Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com>
Fix up the code style for those declarations that should now fit onto one
line, which is all of them that currently do not.
This is needed for dtoc to detect the structs correctly, at present.
Signed-off-by: Simon Glass <sjg@chromium.org>
We use 'priv' for private data but often use 'platdata' for platform data.
We can't really use 'pdata' since that is ambiguous (it could mean private
or platform data).
Rename some of the latter variables to end with 'plat' for consistency.
Signed-off-by: Simon Glass <sjg@chromium.org>
This construct is quite long-winded. In earlier days it made some sense
since auto-allocation was a strange concept. But with driver model now
used pretty universally, we can shorten this to 'auto'. This reduces
verbosity and makes it easier to read.
Coincidentally it also ensures that every declaration is on one line,
thus making dtoc's job easier.
Signed-off-by: Simon Glass <sjg@chromium.org>
The fix in commit b7adcdd073c0 has the side-effect that the regulator
will be disabled when requesting the relevant gpio in
regulator_common_ofdata_to_platdata() and enabled in
regulator_pre_probe() when the regulator was already enabled.
This leads to a short interruption in the 3.3V power to the PCIe
slot on the firefly-rk3399 which makes an ADATA SX8000NP NVMe SSD
unhappy.
Fix this by setting the GPIOD_IS_OUT_ACTIVE flag again when the
'regulator-boot-on' property is set, but check for this property
explicitly instead of relying on the "boot_on" member of
the uclass platdata.
Signed-off-by: Mark Kettenis <kettenis@openbsd.org>
Tested-by: Patrice Chotard <patrice.chotard@st.com>
The commit e8e9715df2d4 ("regulator: fixed: Modify enable-active-high behavior")
fixed the regulator driver behavior when 'enable-active-high' is defined.
Unfortunately, this patch used dm_regulator_platdata()'s "boot_on" member
to set GPIOD_IS_OUT_ACTIVE flag and enable the regulator.
The issue here is that regulator_common_ofdata_to_platdata() is called
_before_ regulator_pre_probe() function in which the 'regulator-boot-on'
property is asserted.
As a result the GPIOD_IS_OUT_ACTIVE flag is not set and gpio_request_by_name()
called in the former function is not enabling the regulator.
This is problematic for e.g. i.MX ethernet driver, which then tries to
perform initialization without power (and fails).
The solution here is to explicitly enable regulator in regulator_pre_probe()
callback only when 'regulator-boot-on' property is present in device tree.
The GPIOD_IS_OUT_ACTIVE flag is not set at all, but relevant gpio is
requested.
Signed-off-by: Lukasz Majewski <lukma@denx.de>
Reviewed-by: Patrice Chotard <patrice.chotard@st.com>
Tested-by: Patrice Chotard <patrice.chotard@st.com>
Fixed regulators don't have a set_value method. Therefore, trying to
set their value will always return -ENOSYS.
Signed-off-by: Sven Schwermer <sven@svenschwermer.de>
Cc: Jaehoon Chung <jh80.chung@samsung.com>
Cc: Peng Fan <peng.fan@nxp.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Changing voltage and enabling regulator might require delays so the
regulator stabilizes at expected level.
Add support for "regulator-ramp-delay" binding which can introduce
required time to both enabling the regulator and to changing the
voltage.
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Tested-by: Anand Moon <linux.amoon@gmail.com>
Signed-off-by: Minkyu Kang <mk7.kang@samsung.com>
regulator_set_enable() api throws an error in the following three cases:
- when requested to disable an always-on regulator
- when set_enable() ops not provided by regulator driver
- when enabling is actually failed.(Error returned by the regulator driver)
Sometimes consumer drivers doesn't want to track the first two scenarios
and just need to worry about the case where enabling is actually failed.
But it is also a good practice to have an error value returned in the
first two cases.
So introduce an api regulator_set_enable_if_allowed() which ignores the
first two error cases and returns an error as given by regulator driver.
Consumer drivers can use this api need not worry about the first two
error conditions.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
This reverts commit e17e0ceb83538c015a50b965547f2f4d38f81c5d.
It is advised to return an error when trying to disable an always-on
regulator and let the consumer driver handle the error if needed.
Reviewed-by: Simon Glass <sjg@chromium.org>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
commit 4f86a724e82c0 ("power: regulator: denied disable on always-on
regulator") throws an error when requested to disable an always-on
regulator. It is right that an always-on regulator should not be
attempted to be disabled. But at the same time regulator framework
should not return an error when such request is received. Instead
it should just return success without attempting to disable the
specified regulator. This is because the requesting driver will
not have the idea if the regulator is always-on or not. The
requesting driver will always try to enable/disable regulator as
per the required flow. So it is upto regulator framework to not
break such scenarios.
Fixes: 4f86a724e82c0 ("power: regulator: denied disable on always-on regulator")
Reported-by: Jean-Jacques Hiblot <jjhiblot@ti.com>
Reviewed-by: Faiz Abbas <faiz_abbas@ti.com>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Don't disable regulator which are tagged as "regulator-always-on" in DT.
Signed-off-by: Patrick Delaunay <patrick.delaunay@st.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Jack Mitchell <jack@embed.me.uk>
Tested-by: Jack Mitchell <jack@embed.me.uk>
Signed-off-by: Patrice Chotard <patrice.chotard@st.com>
Reviewed-by: Richard Röjfors <richard@puffinpack.se>
Tested-by: Richard Röjfors <richard@puffinpack.se>
Reviewed-by: Felix Brack <fb@ltec.ch>
Tested-by: Felix Brack <fb@ltec.ch>
When U-Boot started using SPDX tags we were among the early adopters and
there weren't a lot of other examples to borrow from. So we picked the
area of the file that usually had a full license text and replaced it
with an appropriate SPDX-License-Identifier: entry. Since then, the
Linux Kernel has adopted SPDX tags and they place it as the very first
line in a file (except where shebangs are used, then it's second line)
and with slightly different comment styles than us.
In part due to community overlap, in part due to better tag visibility
and in part for other minor reasons, switch over to that style.
This commit changes all instances where we have a single declared
license in the tag as both the before and after are identical in tag
contents. There's also a few places where I found we did not have a tag
and have introduced one.
Signed-off-by: Tom Rini <trini@konsulko.com>
We have a large number of places where while we historically referenced
gd in the code we no longer do, as well as cases where the code added
that line "just in case" during development and never dropped it.
Signed-off-by: Tom Rini <trini@konsulko.com>
This file does not report a few possible errors and one message is missing
a newline. Fix these.
Signed-off-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com>
At present devices use a simple integer offset to record the device tree
node associated with the device. In preparation for supporting a live
device tree, which uses a node pointer instead, refactor existing code to
access this field through an inline function.
Signed-off-by: Simon Glass <sjg@chromium.org>
Currently the specific set ops functions are directly
called without any check for min/max current limits for a regulator.
Check for them and proceed.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Fixed checking of current limits:
Signed-off-by: Simon Glass <sjg@chromium.org>
Currently the specific set ops functions are directly
called without any check for voltage limits for a regulator.
Check for them and proceed.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Fixed checking of voltate limits:
Signed-off-by: Simon Glass <sjg@chromium.org>
In case we want to force a particular value on a regulator
irrespective of the min/max constraints for testing purposes
one can call regulator_set_value_force function.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Some regulators will not implement any operations (e.g. fixed regulators).
This is not an error, so allow the autoset process to continue when one
of these regulators is found.
Signed-off-by: Simon Glass <sjg@chromium.org>
The currect PMIC debugging is a little confusing. Adjust it so that it is
clear whether the operation succeeded or failed. Also, avoid creating a new
error return value when a perfectly good one is already available.
Signed-off-by: Simon Glass <sjg@chromium.org>
Some devices are supplied by configurable regulator's output.
But there was no function for getting it. This commit adds
function, that allows for getting the supply device by it's phandle.
The returned regulator device can be used with regulator uclass's API.
Signed-off-by: Przemyslaw Marczak <p.marczak@samsung.com>
Cc: Simon Glass <sjg@chromium.org>
Signed-off-by: Minkyu Kang <mk7.kang@samsung.com>
If there is no property named 'regulator-name' for regulators,
choose node name instead, but not directly return failure value.
Signed-off-by: Peng Fan <Peng.Fan@freescale.com>
Cc: Przemyslaw Marczak <p.marczak@samsung.com>
Cc: Simon Glass <sjg@chromium.org>
Not all regulators can be set up automatically. Adjust the code so that
regulators_enable_boot_on() will return success when some are skipped.
Only genuine errors are reported.
Signed-off-by: Simon Glass <sjg@chromium.org>
Acked-by: Przemyslaw Marczak <p.marczak@samsung.com>
To reduce unnecessary code size in an uncommon code path, use debug()
where possible(). The driver returns an error which indicates failure.
Signed-off-by: Simon Glass <sjg@chromium.org>
Tested-by: Przemyslaw Marczak <p.marczak@samsung.com>
Acked-by: Przemyslaw Marczak <p.marczak@samsung.com>
The device tree provides information about which regulators should be
on at boot, or always on. Use this to set them up automatically.
Signed-off-by: Simon Glass <sjg@chromium.org>
Tested-by: Przemyslaw Marczak <p.marczak@samsung.com>
Acked-by: Przemyslaw Marczak <p.marczak@samsung.com>
The regulator_autoset() function mixes printf() output and PMIC adjustment
code. It provides a boolean to control the output. It is better to avoid
missing logic and output, and this permits a smaller SPL code size. So
split the output into a separate function.
Also rename the function to have a by_name() suffix, since we would like
to be able to pass a device when we know it, and thus avoid the name
search.
Signed-off-by: Simon Glass <sjg@chromium.org>
Tested-by: Przemyslaw Marczak <p.marczak@samsung.com>
Acked-by: Przemyslaw Marczak <p.marczak@samsung.com>